Rayson PatchBond Epoxy Interior

Rayson PatchBond TX80

Rayson PatchBond TX80 is a two-component, solvent-free thixotropic epoxy adhesive and repair compound with exceptional sag resistance that bonds and fills on vertical, overhead and even mat-damp concrete surfaces.

Best for

Best for non-sag repairs, crack and joint filling, and structural bonding on vertical and overhead surfaces — including damp concrete.

Real product · Interactive depth view Rayson PatchBond
Rayson PatchBond TX80 real product packaging and supplied components
Move to inspect the product
Product system Rayson PatchBond TX80
Part A 4 or 8 kg / Part B 2 or 4 kg per set RY-TDS-902
Why specify Rayson PatchBond TX80

Rayson PatchBond TX80 has one clearly defined, verifiable job in the coating system.

Rayson PatchBond TX80 is a two-component, solvent-free thixotropic epoxy adhesive and repair compound with exceptional sag resistance that bonds and fills on vertical, overhead and even mat-damp concrete surfaces. Best for non-sag repairs, crack and joint filling, and structural bonding on vertical and overhead surfaces — including damp concrete.

01

Exceptional sag resistance — holds 13–15 mm on vertical surfaces

Filling voids, cracks and joints in concrete

02

Moisture-tolerant — bonds to mat-damp concrete

Bonding metal profiles and fixtures onto vertical surfaces

03

Hardens without shrinkage; impermeable to liquids and water vapour

Repairs to fibre cement, stone, ceramics, wood, brick and masonry

Representative application environment for Rayson PatchBond TX80
Non-sag structural repair

Repair vertical and overhead concrete—without sag.

A moisture-tolerant thixotropic epoxy that bonds, fills and holds its shape on vertical, overhead and damp concrete.

From substrate to service

A controlled route to applying Rayson PatchBond TX80.

This sequence supports early planning. It does not replace the current Technical Data Sheet, approved method statement or project-specific technical review.

  1. 01

    Inspect and prepare the substrate

    Concrete, including wet or mat-damp surfaces (no standing water)

  2. 02

    Prepare the material as specified

    Two pre-weighed parts, mix ratio 2:1 (A:B) by weight; mix with a low-speed drill and paddle for at least 3–5 minutes, avoiding aeration; pot life up to 30 minutes at 28 °C

  3. 03

    Apply with the correct tools

    Recommended methods: Spatula, Trowel or notched trowel, Gloved hand application. Confirm coat count and thickness for the project.

  4. 04

    Protect through the required cure

    Protect the applied surface and confirm the required cure before returning it to service.

Coating system cutaway

Every layer has a job—from prepared substrate to service surface.

This diagram explains a typical system position, not a fixed specification. Primer, body coat, finish, thickness and detailing must be confirmed for the project.

Position in the system Standalone coating

Rayson PatchBond TX80 serves as the standalone coating. Confirm the complete build-up against the substrate, exposure and project requirements.

Related system products

Review primers, body layers, finishes or specialist components connected to this product.

  1. Reinstated surface / subsequent coatingSelected for the repair scope and subsequent system
  2. Rayson PatchBond TX80Standalone coating · Epoxy
  3. Correctly prepared substrateConcrete, including wet or mat-damp surfaces (no standing water)
Technical planning data

Four project facts for faster system screening.

These current product figures support early selection. Confirm the final build-up, quantity and application conditions against the Technical Data Sheet and site conditions.

Coverage
Coverage

Approximately up to 1.90 kg/m² per mm of thickness (theoretical, subject to conditions and porosity)

Mixing & working time
Mixing

Two pre-weighed parts, mix ratio 2:1 (A:B) by weight; mix with a low-speed drill and paddle for at least 3–5 minutes, avoiding aeration; pot life up to 30 minutes at 28 °C

Drying & curing
Curing

Refer to the Technical Data Sheet

Pack configuration
Pack

Part A 4 or 8 kg / Part B 2 or 4 kg per set

Suitability check

Confirm the substrate and real service environment before specifying.

02

Choose something else when

  • Minimum substrate temperature 10 °C; curing between +10 °C and +30 °C
  • Layer thickness when bonding vertical metal profiles must not exceed 5 mm
  • Bonded vertical elements must be propped for at least 12 hours
  • Substrate may be mat-damp but must have no standing water
  • Large horizontal floor reinstatement — Rayson MortarBond EM90 is the better tool
  • Substrates with standing water or active water ingress
  • Applications below 10 °C substrate temperature
  • Movement joints requiring a flexible sealant — cured epoxy is rigid

Other Rayson products to evaluate

These links continue the comparison; they are not automatic substitutes. Confirm the substrate, exposure and complete build-up before selection.

Substrate requirements
  • Concrete, including wet or mat-damp surfaces (no standing water)
  • Fibre cement, hard natural stone and ceramics
  • Wood, polyester, epoxy and glass
  • Bricks, mortar and masonry
Technical documents and project support

Ready to specify Rayson PatchBond TX80? Give Rayson the site conditions.

Send the area, substrate condition, expected traffic or exposure, required finish and programme. The technical team can help review the system build-up and estimated quantity.

Common technical questions

What to know before specifying Rayson PatchBond TX80.

Will it sag on a wall or ceiling?

No — the thixotropic body holds around 13–15 mm on vertical faces at 28 °C without slumping, which is what it is designed for.

Can it be applied to damp concrete?

Yes, to mat-damp concrete with no standing water — the formulation is moisture-tolerant and builds durable bonds on wet substrates.

Why must mixing avoid aeration?

Whipped-in air weakens the compound and leaves voids in the repair. Mix with a low-speed drill for 3–5 minutes rather than a fast one.

How long must bonded fixtures be supported?

Prop vertical bonded elements for at least 12 hours while the epoxy develops handling strength.

When has it fully cured?

Test values reference 7-day curing; check the full cure schedule with our technical team for load-critical work.

TX80 or EM90 — which repair product do I need?

TX80 for vertical, overhead, damp or bonding work where sag resistance matters; EM90 for horizontal floor patches needing maximum compressive strength under traffic.

Related products

Rayson MortarBond EM90 — Repair mortars & compounds
Repair PatchBond

Rayson MortarBond EM90

Three-part · 33 kg kit

Rayson MortarBond EM90 is a three-pack, solvent-free epoxy mortar — resin, hardener and graded aggregate — that reinstates concrete floors with a non-shrink, highly abrasion-resistant repair.

Surfaces
Concrete
Chemistry
Epoxy
Rayson PrimeBond E20 — Primers & bonding coats
Prime PrimeBond

Rayson PrimeBond E20

Solvent-free · damp tolerant

Rayson PrimeBond E20 is a two-component, medium-viscosity, solvent-free epoxy bonding primer that anchors resin floor systems to concrete, screed, asphalt and prepared metal — on dry or damp substrates.

Surfaces
Concrete, Cement screed
Chemistry
Epoxy
Rayson LevelShield SL120 — Self-levelling floor systems
Body LevelShield

Rayson LevelShield SL120

Self-smoothing · solvent-free

Rayson LevelShield SL120 is a solvent-free, two-component, self-smoothing epoxy floor system that delivers a seamless wearing surface with medium to heavy chemical resistance and high mechanical strength.

Surfaces
Concrete
Chemistry
Epoxy