100% solids, solvent-free — install in enclosed areas without solvent odour
Areas requiring resistance to mechanical loading and abrasion
Rayson LevelShield SL120 is a solvent-free, two-component, self-smoothing epoxy floor system that delivers a seamless wearing surface with medium to heavy chemical resistance and high mechanical strength.
Best for production areas, warehouses, loading bays and clean environments that need a seamless, hard-wearing, self-levelled epoxy floor.
Rayson LevelShield SL120 is a solvent-free, two-component, self-smoothing epoxy floor system that delivers a seamless wearing surface with medium to heavy chemical resistance and high mechanical strength. Best for production areas, warehouses, loading bays and clean environments that need a seamless, hard-wearing, self-levelled epoxy floor.
Areas requiring resistance to mechanical loading and abrasion
Pharmaceutical facilities and clean rooms
Warehouses, storage areas and loading bays
A solvent-free epoxy floor that creates a strong, easy-clean wearing surface for production areas and warehouses.
This sequence supports early planning. It does not replace the current Technical Data Sheet, approved method statement or project-specific technical review.
Mechanically prepared concrete (minimum 28 days old, moisture content below 5%)
Two pre-weighed parts, mix ratio 4:1 (A:B) by weight; mix mechanically for at least 2–3 minutes; pot life up to 20 minutes at 28 °C
Recommended methods: Steel trowel, Notched rake, Squeegee and roller, Spike roller to de-aerate. Confirm coat count and thickness for the project.
At +20 °C: foot traffic 24 h, light traffic 4 days, full cure 7 days. At +30 °C: foot traffic 18 h, light traffic 2 days, full cure 5 days. Recoat window 24 h–2 days at +20 °C (16 h–1 day at +30 °C)
This diagram explains a typical system position, not a fixed specification. Primer, body coat, finish, thickness and detailing must be confirmed for the project.
Rayson LevelShield SL120 serves as the body coat. Confirm the complete build-up against the substrate, exposure and project requirements.
Review primers, body layers, finishes or specialist components connected to this product.
These current product figures support early selection. Confirm the final build-up, quantity and application conditions against the Technical Data Sheet and site conditions.
Approximately 1.6–2.0 kg/m² as a self-smoothing wearing coat, subject to filling grade, porosity, level variation and wastage
Two pre-weighed parts, mix ratio 4:1 (A:B) by weight; mix mechanically for at least 2–3 minutes; pot life up to 20 minutes at 28 °C
At +20 °C: foot traffic 24 h, light traffic 4 days, full cure 7 days. At +30 °C: foot traffic 18 h, light traffic 2 days, full cure 5 days. Recoat window 24 h–2 days at +20 °C (16 h–1 day at +30 °C)
Part A 16 kg / Part B 4 kg per set
These links continue the comparison; they are not automatic substitutes. Confirm the substrate, exposure and complete build-up before selection.
Send the area, substrate condition, expected traffic or exposure, required finish and programme. The technical team can help review the system build-up and estimated quantity.
It is applied as a self-smoothing wearing coat at a consumption of roughly 1.6–2.0 kg/m²; the achieved thickness depends on filling grade and levelness of the slab. Confirm the build-up for your traffic with our technical team.
Indicatively, foot traffic within about a day, light traffic in 2–4 days and full cure in 5–7 days depending on temperature — faster in warm conditions.
Yes. Apply over a suitable Rayson epoxy primer such as PrimeBond E20 on mechanically prepared concrete to guarantee adhesion and avoid pinholes from substrate porosity.
The system is rated for medium to heavy chemical resistance. For a specific chemical exposure — substance, concentration, temperature and contact time — always verify against the resistance schedule with our technical team.
Mixed material stays workable for only around 20 minutes at 28 °C and cures faster in bulk. Batching, placement and spike-rolling need to run as a continuous, well-crewed operation.
Yes — the seamless, easy-to-clean surface and solvent-free installation suit pharmaceutical facilities and clean rooms.
Solvent-free · damp tolerant
Rayson PrimeBond E20 is a two-component, medium-viscosity, solvent-free epoxy bonding primer that anchors resin floor systems to concrete, screed, asphalt and prepared metal — on dry or damp substrates.
Three-part · 33 kg kit
Rayson MortarBond EM90 is a three-pack, solvent-free epoxy mortar — resin, hardener and graded aggregate — that reinstates concrete floors with a non-shrink, highly abrasion-resistant repair.
Two-part epoxy repair system
Rayson PatchBond TX80 is a two-component, solvent-free thixotropic epoxy adhesive and repair compound with exceptional sag resistance that bonds and fills on vertical, overhead and even mat-damp concrete surfaces.
Conductive ESD flooring
Rayson StaticGuard CX90 is a two-component, solvent-free conductive epoxy flooring that gives ESD-protected areas a self-smoothing, permanently conductive, chemically resistant wearing surface.
Rayson assistant
Answers from Rayson's own product information
Guidance only — confirm specifications with the Rayson technical team.