Rayson StaticGuard Epoxy Interior

Rayson StaticGuard CX90

Rayson StaticGuard CX90 is a two-component, solvent-free conductive epoxy flooring that gives ESD-protected areas a self-smoothing, permanently conductive, chemically resistant wearing surface.

Best for

Best for electronics production, data centres and other ESD-protected areas that need a grounded, seamless floor with high mechanical strength.

Real product · Interactive depth view Rayson StaticGuard
Rayson StaticGuard CX90 real product packaging and supplied components
Move to inspect the product
Product system Rayson StaticGuard CX90
Part A 16 kg / Part B 4 kg per set RY-TDS-501
Why specify Rayson StaticGuard CX90

Rayson StaticGuard CX90 has one clearly defined, verifiable job in the coating system.

Rayson StaticGuard CX90 is a two-component, solvent-free conductive epoxy flooring that gives ESD-protected areas a self-smoothing, permanently conductive, chemically resistant wearing surface. Best for electronics production, data centres and other ESD-protected areas that need a grounded, seamless floor with high mechanical strength.

01

Permanent conductivity through the coating body (average 10⁴–10⁶ ohms)

ESD-protected and dissipative-compliant areas

02

100% solids, solvent-free and low VOC

Electronics facilities and data centres

03

Self-smoothing, seamless, easy-to-clean finish

Antistatic flooring and walls

Representative application environment for Rayson StaticGuard CX90
ESD flooring in service

Control static from the floor up.

A permanently conductive, seamless epoxy floor for electronics production, data centres and other ESD-protected areas.

From substrate to service

A controlled route to applying Rayson StaticGuard CX90.

This sequence supports early planning. It does not replace the current Technical Data Sheet, approved method statement or project-specific technical review.

  1. 01

    Inspect and prepare the substrate

    Mechanically prepared concrete (minimum 28 days old, moisture content below 5%)

  2. 02

    Prepare the material as specified

    Two pre-weighed parts, mix ratio 4:1 (A:B) by weight; mix mechanically for at least 2–3 minutes; pot life up to 25 minutes at 28 °C

  3. 03

    Apply with the correct tools

    Recommended methods: Steel trowel, Notched rake, Squeegee and roller, Spike roller immediately after trowelling. Confirm coat count and thickness for the project.

  4. 04

    Protect through the required cure

    Full cure approximately 7 days; minimise heavy traffic for 72 hours after application

Coating system cutaway

Every layer has a job—from prepared substrate to service surface.

This diagram explains a typical system position, not a fixed specification. Primer, body coat, finish, thickness and detailing must be confirmed for the project.

Position in the system Finish

Rayson StaticGuard CX90 serves as the finish. Confirm the complete build-up against the substrate, exposure and project requirements.

Related system products

Review primers, body layers, finishes or specialist components connected to this product.

  1. Rayson StaticGuard CX90Finish · Epoxy
  2. Compatible system baseSelected for the required specialist performance
  3. Correctly prepared substrateMechanically prepared concrete (minimum 28 days old, moisture content below 5%)
Technical planning data

Four project facts for faster system screening.

These current product figures support early selection. Confirm the final build-up, quantity and application conditions against the Technical Data Sheet and site conditions.

Coverage
Coverage

Minimum 2.25 kg binder per m² per coat at approximately 1.5 mm (optionally +0.25 kg quartz sand); approximately 5–8 m²/L at 75 µm DFT for thin coats; maximum ~2.5 kg/m² binder plus filler at 1.5 mm

Mixing & working time
Mixing

Two pre-weighed parts, mix ratio 4:1 (A:B) by weight; mix mechanically for at least 2–3 minutes; pot life up to 25 minutes at 28 °C

Drying & curing
Curing

Full cure approximately 7 days; minimise heavy traffic for 72 hours after application

Pack configuration
Pack

Part A 16 kg / Part B 4 kg per set

Suitability check

Confirm the substrate and real service environment before specifying.

01

Choose it when

  • ESD-protected and dissipative-compliant areas
  • Electronics facilities and data centres
  • Antistatic flooring and walls
  • EMI and RFI shielding installations
  • Pharmaceutical facilities and aerospace hangars
  • Warehouses and storage areas requiring static control

Relevant applications

Relevant industries

02

Choose something else when

  • Applying above the stated film thickness reduces conductivity — thickness control is critical
  • Measured resistance readings are affected by ESD clothing, ambient conditions, measurement equipment, floor cleaning and test personnel
  • Minimum substrate temperature 5 °C; curing between +10 °C and +35 °C; concrete moisture content maximum 5%
  • Requires planned earthing points and post-installation resistance verification
  • Areas with no earthing provision — conductivity is useless without a ground path
  • Exterior UV-exposed surfaces
  • Thick-build applications beyond the stated film thickness — conductivity drops
  • Substrates with moisture above 5%

Other Rayson products to evaluate

These links continue the comparison; they are not automatic substitutes. Confirm the substrate, exposure and complete build-up before selection.

Substrate requirements
  • Mechanically prepared concrete (minimum 28 days old, moisture content below 5%)
  • Substrate pull-off strength above 1.5 N/mm² after preparation
Technical documents and project support

Ready to specify Rayson StaticGuard CX90? Give Rayson the site conditions.

Send the area, substrate condition, expected traffic or exposure, required finish and programme. The technical team can help review the system build-up and estimated quantity.

Common technical questions

What to know before specifying Rayson StaticGuard CX90.

Is StaticGuard CX90 conductive or dissipative?

Its average electrostatic behaviour is in the 10⁴–10⁶ ohm range, which sits in conductive ESD territory. The reading achieved on site also depends on installation, earthing, cleaning and how the measurement is taken — always verify against your facility standard.

Why must the film thickness not be exceeded?

Conductivity depends on the conductive network through the coating. Applying thicker than specified increases resistance and can push the floor out of its target range.

How is the floor earthed?

Grounding points are installed as part of the system, connected to the building earth by the electrical contractor. Agree the earthing layout with the facility engineer before installation.

How do we prove the floor meets its ESD target?

With documented resistance testing after full cure, using the measurement method your facility standard specifies. Rayson recommends retesting on a scheduled basis thereafter.

What cleaning products can be used?

Use cleaners that do not leave insulating films — waxes and polymer polishes can raise surface resistance and defeat the static control.

When can production equipment move back in?

Keep heavy traffic off for at least 72 hours and allow around 7 days for full cure before resistance verification. Confirm programme timings with our technical team.

Related products

Rayson PrimeBond E20 — Primers & bonding coats
Prime PrimeBond

Rayson PrimeBond E20

Solvent-free · damp tolerant

Rayson PrimeBond E20 is a two-component, medium-viscosity, solvent-free epoxy bonding primer that anchors resin floor systems to concrete, screed, asphalt and prepared metal — on dry or damp substrates.

Surfaces
Concrete, Cement screed
Chemistry
Epoxy
Rayson LevelShield SL120 — Self-levelling floor systems
Body LevelShield

Rayson LevelShield SL120

Self-smoothing · solvent-free

Rayson LevelShield SL120 is a solvent-free, two-component, self-smoothing epoxy floor system that delivers a seamless wearing surface with medium to heavy chemical resistance and high mechanical strength.

Surfaces
Concrete
Chemistry
Epoxy
Rayson PatchBond TX80 — Repair mortars & compounds
Repair PatchBond

Rayson PatchBond TX80

Two-part epoxy repair system

Rayson PatchBond TX80 is a two-component, solvent-free thixotropic epoxy adhesive and repair compound with exceptional sag resistance that bonds and fills on vertical, overhead and even mat-damp concrete surfaces.

Surfaces
Concrete, Walls
Chemistry
Epoxy