Permanent conductivity through the coating body (average 10⁴–10⁶ ohms)
ESD-protected and dissipative-compliant areas
Rayson StaticGuard CX90 is a two-component, solvent-free conductive epoxy flooring that gives ESD-protected areas a self-smoothing, permanently conductive, chemically resistant wearing surface.
Best for electronics production, data centres and other ESD-protected areas that need a grounded, seamless floor with high mechanical strength.
Rayson StaticGuard CX90 is a two-component, solvent-free conductive epoxy flooring that gives ESD-protected areas a self-smoothing, permanently conductive, chemically resistant wearing surface. Best for electronics production, data centres and other ESD-protected areas that need a grounded, seamless floor with high mechanical strength.
ESD-protected and dissipative-compliant areas
Electronics facilities and data centres
Antistatic flooring and walls
A permanently conductive, seamless epoxy floor for electronics production, data centres and other ESD-protected areas.
This sequence supports early planning. It does not replace the current Technical Data Sheet, approved method statement or project-specific technical review.
Mechanically prepared concrete (minimum 28 days old, moisture content below 5%)
Two pre-weighed parts, mix ratio 4:1 (A:B) by weight; mix mechanically for at least 2–3 minutes; pot life up to 25 minutes at 28 °C
Recommended methods: Steel trowel, Notched rake, Squeegee and roller, Spike roller immediately after trowelling. Confirm coat count and thickness for the project.
Full cure approximately 7 days; minimise heavy traffic for 72 hours after application
This diagram explains a typical system position, not a fixed specification. Primer, body coat, finish, thickness and detailing must be confirmed for the project.
Rayson StaticGuard CX90 serves as the finish. Confirm the complete build-up against the substrate, exposure and project requirements.
Review primers, body layers, finishes or specialist components connected to this product.
These current product figures support early selection. Confirm the final build-up, quantity and application conditions against the Technical Data Sheet and site conditions.
Minimum 2.25 kg binder per m² per coat at approximately 1.5 mm (optionally +0.25 kg quartz sand); approximately 5–8 m²/L at 75 µm DFT for thin coats; maximum ~2.5 kg/m² binder plus filler at 1.5 mm
Two pre-weighed parts, mix ratio 4:1 (A:B) by weight; mix mechanically for at least 2–3 minutes; pot life up to 25 minutes at 28 °C
Full cure approximately 7 days; minimise heavy traffic for 72 hours after application
Part A 16 kg / Part B 4 kg per set
These links continue the comparison; they are not automatic substitutes. Confirm the substrate, exposure and complete build-up before selection.
Send the area, substrate condition, expected traffic or exposure, required finish and programme. The technical team can help review the system build-up and estimated quantity.
Its average electrostatic behaviour is in the 10⁴–10⁶ ohm range, which sits in conductive ESD territory. The reading achieved on site also depends on installation, earthing, cleaning and how the measurement is taken — always verify against your facility standard.
Conductivity depends on the conductive network through the coating. Applying thicker than specified increases resistance and can push the floor out of its target range.
Grounding points are installed as part of the system, connected to the building earth by the electrical contractor. Agree the earthing layout with the facility engineer before installation.
With documented resistance testing after full cure, using the measurement method your facility standard specifies. Rayson recommends retesting on a scheduled basis thereafter.
Use cleaners that do not leave insulating films — waxes and polymer polishes can raise surface resistance and defeat the static control.
Keep heavy traffic off for at least 72 hours and allow around 7 days for full cure before resistance verification. Confirm programme timings with our technical team.
Solvent-free · damp tolerant
Rayson PrimeBond E20 is a two-component, medium-viscosity, solvent-free epoxy bonding primer that anchors resin floor systems to concrete, screed, asphalt and prepared metal — on dry or damp substrates.
Self-smoothing · solvent-free
Rayson LevelShield SL120 is a solvent-free, two-component, self-smoothing epoxy floor system that delivers a seamless wearing surface with medium to heavy chemical resistance and high mechanical strength.
Two-part epoxy repair system
Rayson PatchBond TX80 is a two-component, solvent-free thixotropic epoxy adhesive and repair compound with exceptional sag resistance that bonds and fills on vertical, overhead and even mat-damp concrete surfaces.
Rayson assistant
Answers from Rayson's own product information
Guidance only — confirm specifications with the Rayson technical team.