Rayson UraForce Polyurethane Interior & exterior

Rayson UraForce WB52

Rayson UraForce WB52 is a two-component, water-based aliphatic urethane floor topcoat — low-VOC, low-odour and UV-resistant — that can be combined with broadcast aggregate for an anti-slip finish.

Best for

Best for durable, low-odour floor topcoats in schools, offices, retail and car park areas, over Rayson PrimeBond W10 primer.

Real product · Interactive depth view Rayson UraForce
Rayson UraForce WB52 real product packaging and supplied components
Move to inspect the product
Product system Rayson UraForce WB52
Part A 4 kg or 18 kg pail + Part B 1 kg or 2 kg pail RY-TDS-706
Why specify Rayson UraForce WB52

Rayson UraForce WB52 has one clearly defined, verifiable job in the coating system.

Rayson UraForce WB52 is a two-component, water-based aliphatic urethane floor topcoat — low-VOC, low-odour and UV-resistant — that can be combined with broadcast aggregate for an anti-slip finish. Best for durable, low-odour floor topcoats in schools, offices, retail and car park areas, over Rayson PrimeBond W10 primer.

01

Low VOC and low odour — occupied-building friendly

UV-resistant topcoat for concrete floors

02

Excellent abrasion and staining resistance (Class 5, preliminary testing)

Topcoat finishes on hard surfaces such as stone and limestone

03

Non-yellowing with 1,000 h QUV weathering performance (preliminary testing)

Hygienic coatings for walls and floors

Representative application environment for Rayson UraForce WB52
Low-odour floor finish

Durable protection for spaces that stay active.

A UV-resistant water-based urethane topcoat for schools, offices, retail and car-park areas, with optional anti-slip aggregate.

From substrate to service

A controlled route to applying Rayson UraForce WB52.

This sequence supports early planning. It does not replace the current Technical Data Sheet, approved method statement or project-specific technical review.

  1. 01

    Inspect and prepare the substrate

    Mechanically prepared concrete (minimum 28 days old, moisture content below 5%)

  2. 02

    Prepare the material as specified

    Two pre-weighed parts, mix ratio as shown on the supplied set size (4:1 or 9:1 A:B by weight); stir parts separately, combine and mix with a slow-speed drill and paddle until uniform; pot life 6 hours at 25 °C

  3. 03

    Apply with the correct tools

    Recommended methods: Short-bristled brush, Roller. Confirm coat count and thickness for the project.

  4. 04

    Protect through the required cure

    Surface dry 2 hours at 28 °C; trafficable after 3 hours

Coating system cutaway

Every layer has a job—from prepared substrate to service surface.

This diagram explains a typical system position, not a fixed specification. Primer, body coat, finish, thickness and detailing must be confirmed for the project.

Position in the system Finish

Rayson UraForce WB52 serves as the finish. Confirm the complete build-up against the substrate, exposure and project requirements.

Related system products

Review primers, body layers, finishes or specialist components connected to this product.

  1. Rayson UraForce WB52Finish · Polyurethane
  2. Compatible body coat / baseProvides the required thickness and continuity beneath the finish
  3. Approved primer / baseIncluded when required by the system design
  4. Correctly prepared substrateMechanically prepared concrete (minimum 28 days old, moisture content below 5%)
Technical planning data

Four project facts for faster system screening.

These current product figures support early selection. Confirm the final build-up, quantity and application conditions against the Technical Data Sheet and site conditions.

Coverage
Coverage

Refer to the Technical Data Sheet

Mixing & working time
Mixing

Two pre-weighed parts, mix ratio as shown on the supplied set size (4:1 or 9:1 A:B by weight); stir parts separately, combine and mix with a slow-speed drill and paddle until uniform; pot life 6 hours at 25 °C

Drying & curing
Curing

Surface dry 2 hours at 28 °C; trafficable after 3 hours

Pack configuration
Pack

Part A 4 kg or 18 kg pail + Part B 1 kg or 2 kg pail

Suitability check

Confirm the substrate and real service environment before specifying.

02

Choose something else when

  • Minimum substrate temperature 5 °C; minimum mixing temperature 10 °C; minimum curing temperature 5 °C
  • Mixed material must be used within its pot life; cures faster in hot weather and in large batches
  • Performance data supported by laboratory testing
  • Thin-film topcoat — apply minimum 2 coats over the primed system
  • Heavy forklift or industrial traffic without an appropriate body coat
  • Chemical containment or immersion service
  • Unprimed, unprepared substrates

Other Rayson products to evaluate

These links continue the comparison; they are not automatic substitutes. Confirm the substrate, exposure and complete build-up before selection.

Substrate requirements
  • Mechanically prepared concrete (minimum 28 days old, moisture content below 5%)
  • Mineral substrates
  • Stone and limestone
  • Walls and floors
Technical documents and project support

Ready to specify Rayson UraForce WB52? Give Rayson the site conditions.

Send the area, substrate condition, expected traffic or exposure, required finish and programme. The technical team can help review the system build-up and estimated quantity.

Common technical questions

What to know before specifying Rayson UraForce WB52.

How quickly can a coated area reopen?

Indicatively surface dry in 2 hours and trafficable in about 3 at 28 °C. Allow longer before wet cleaning or heavy use; confirm programme timings with our technical team.

Does it resist staining?

Testing records Class 5 staining resistance against used engine oil, olive oil, coffee with milk and black rubber — strong results.

How is the anti-slip version built?

Broadcast fine aggregate into the wet PrimeBond W10 primer, sweep off the excess when dry, then seal with two coats of WB52. Preliminary testing on this build-up records at least 70 SRV skid resistance.

Is it suitable for exterior use?

Yes — the aliphatic urethane is non-yellowing and has run 1,000 hours of QUV accelerated weathering in preliminary testing.

What primer does it need?

Rayson PrimeBond W10 is the matched water-based primer for this system.

What sheens are available?

Gloss, satin and matt.

Related products

Rayson PrimeBond W10 — Primers & bonding coats
Prime PrimeBond

Rayson PrimeBond W10

Single-pack · water-based

Rayson PrimeBond W10 is a one-component, water-based acrylic primer, sealer and bonding agent for smooth concrete and mineral substrates, applied ahead of Rayson UraForce water-based topcoats.

Surfaces
Concrete, Cement screed
Chemistry
Acrylic
Rayson UraForce HY15 — Polyurethane finishes
Finish UraForce

Rayson UraForce HY15

Single-pack · 24 kg

Rayson UraForce HY15 is a single-component, water-based hybrid urethane — a self-crosslinking acrylic-copolymer-enhanced polyurethane — that roller-coats concrete and mineral surfaces with a fast-drying, stain-resistant, anti-slip finish.

Surfaces
Concrete, Cement screed
Chemistry
Hybrid urethane
Rayson GripSafe AP12 — Anti-slip systems
Specialist GripSafe

Rayson GripSafe AP12

Purpose-built anti-slip system

Rayson GripSafe AP12 is a one-pack, self-crosslinking acrylic primer filler loaded with 0.5–1.5 mm silicate quartz aggregate that builds an anti-slip texture directly onto concrete and asphalt.

Surfaces
Concrete, Cement screed
Chemistry
Acrylic
Rayson UraForce WB58 — Polyurethane finishes
Finish UraForce

Rayson UraForce WB58

Water-based polyurethane finish

Rayson UraForce WB58 is a two-component, water-based aliphatic polyurethane dispersion topcoat, crosslinked with a PUR hardener, for abrasion-resistant coloured finishes on concrete, metal and mineral surfaces.

Surfaces
Concrete, Walls
Chemistry
Polyurethane